Ο λόγος στασίμων 1:1 ενός κεραιοσυστήματος, δεν συνεπάγεται τον 1:1 λόγο μεταφοράς ισχύος, προς την κεραία!
Showing posts with label Collins 30L-1. Show all posts
Showing posts with label Collins 30L-1. Show all posts

Friday, 3 March 2017

Calibration of the HV probe!

It can be be done the easy way and the easier way!
The easy way is to measure with your DVM a DC voltage of 300 to 500V and then adjust the multi-turn pot to see the same voltage divided by 100. I.e. if you read 420VDC on your DVM, measuring with the 100:1 probe, after you adjust the multi-turn pot, you will see 4.20VDC.
The easier and far more safer way is to measure the Voltage output of your bench power supply and do the same procedure!

 As you can see in the photos, the Vout of mine is 13.854VDC. I adjust then my probe to see 138.54mVDC on the display.

 I am lucky to have an AVO multi meter which can measure HV up to 2500Volts. I use that as a reference and measure the 811's Plate Voltage of my 30L-1 Collins lin-amp. 

 The HV as can be seen in the photo is, lets say, 1930VDC. Using the HV probe with no further adjustment I saw 19.48VDC An error of far less than 5%.

 Wow! Although it is not a precision nor a factory made probe, it works like having a high degree of accuracy!
Even if you see a HV of 2450VDC whereas your actually HV is 2620VDC, the error is 6.5% which is acceptable in my book and then it puts you in the right track if you are trying to locate a fault or anything!
Thank you and 73.
p.s. you can hardly see in the photos that I have encapsulate my probe into a plastic square conduit pipe measuring 13mm X 14.4mm X150mm. It IS safe but not "aesthetically elegant" for my taste so I will think of a different case for it! I'll let you know!

(μιά φορά που η google κατάφερε να μεταφράσει σχεδόν σωστά τα Αγγλικά μου!
Η τελική ρύθμιση μπορεί να γίνει με τον εύκολο τρόπο και τον πιο εύκολο 
τρόπο!
Ο εύκολος τρόπος είναι να μετρηθεί με DVM σας μια τάση συνεχούς 
ρεύματος από 300 έως 500V και στη συνέχεια ρυθμίστε το πολύστροφο 
ποτενσιόμετρο για να δείτε την ίδια τάση διαιρείτε με το 100. Δηλ. αν 
διαβάσετε 420VDC για DVM σας, μετρώντας με το 100: 1 ανιχνευτή κι 
αφού ρυθμίσετε το πολύστροφο ποτενσιόμετρο, θα δείτε 4.20VDC.
Η πιο εύκολη και πολύ πιο ασφαλή τρόπο είναι να μετρηθεί η τάση εξόδου 
του τροφοδοτικού πάγκο σας και να κάνετε την ίδια διαδικασία!
Όπως μπορείτε να δείτε και στις φωτογραφίες, η Vout μου είναι 13.854VDC 
Έχω ρυθμίσει στη συνέχεια αισθητήρα μου για να δω 138.54mVDC στην 
οθόνη του πολυμέτρου.
Είμαι τυχερός που έχω ένα AVO πολύμετρο που μπορεί να μετρήσει HV 
μέχρι 2500Volts. Μπορώ να χρησιμοποιήσω αυτό ως σημείο αναφοράς και 
για την μέτρηση των ανόδων των 811 του 30L-1Collins lin-amp. Το ΗV 
όπως φαίνεται στη φωτογραφία είναι, ας πούμε, 1930VDC. Χρησιμοποιώντας 
τον ανιχνευτή HV χωρίς περαιτέρω προσαρμογή είδα 19.51VDC Ένα σφάλμα 
μικρότερο του 5%.
Ουάου! 
Αν και δεν είναι ένας ακριβής εργοστασιακός ανιχνευτής, λειτουργεί σαν 
να έχει ένα υψηλό βαθμό ακρίβειας!
Ακόμα κι αν δείτε Υψηλή Τάση των 2450VDC ενώ σας πραγματικότητα 
η Υψηλή Τάση είναι 2620VDC, το σφάλμα είναι 6,5%, πράγμα που είναι 
αποδεκτό κατ' εμέ και που στην συνέχεια να σας βάζει στο σωστό δρόμο αν 
προσπαθείτε να εντοπίσετε ένα σφάλμα ή κάτι τέτοιο!
Σας ευχαριστώ και 73.

Thursday, 15 September 2016

ur R is cracked!


Repairing an old friend!
Out of 4 grid resistors, 47R each, one is cracked and the other three shows a resistance of 35R each. Hard driving the amplifier, pays it toll eventually. Sadly enough and it wasn't me the one who did it.


Η υπεροδήγηση έχει συνέπειες. Ίσως όχι στο ακουστικό κομμάτι αφού ο ενισχυτής είναι φανταστικός αλλά, στο οικονομικό. 3€ θα κοστίσουν οι αντιστάσεις ν' αλλαχτούν. Λίγο είναι?!

Wednesday, 22 April 2015

Ουδείς άσφαλτος!



When I bought my Collins 30L-1 years ago, I was living in London and I didn't had the means nor the Hi-Power ATU to test it on the air. All I could do was to check that it was producing power and the HV indication was full scale. After the restoration of the PS board and some minor repairs I put it next to my TS-830s to alight the Aether! I load my rig as I supposed to and started to Tune and Load my Collins. Something was wrong from beginning. The output power was low and the pair of 6146B's was drawing a lot of current. Fiddling with the knobs and buttons I saw the panel light flicker and I smell the “magic smoke”. Due to excessive current draw I had crack open two of the four 20 Ohm resistors at the final board. The reason for that is that the tuned input of the Collins are a bit out of resonance and it shows mismatch and higher than normal SWR. Unlucky their value is a special one so to replace them exactly I have to connect in parallel one 22 Ohm and one 220 Ohm resistor. I have the resistors now and I will replace all four of them next time I will go back to my holiday home.
Don't Panic! (everything is under control. I guess!)
I owe a lot to Dave VK5PDL. Cheers mate!



Η Μεγάλη Εβδομάδα ήταν πραγματικά “μεγάλη”!
Σε πρώτη φάση το TS-830 έδειξε να συνεργάζεται άψογα με τον Collins. Μετά ξεκίνησε το πρόβλημα. Η είσοδος του ενισχυτή και η Σύνθετη Αντίσταση δεν ήταν 50 Ωμ αλλά κάτι παραπλήσιο. Αυτό είχε σαν αποτέλεσμα το μηχάνημα να βλέπει δυσπροσαρμογή και αυτή με την σειρά της να τινάζει στον αέρα τον συντονισμό των 6146. Κάποια στιγμή που θέλησα να τα δώσω όλα στο ενισχυτή μεταβάλλοντας ταυτόχρονα τον συντονισμό της κεραίας.
Με τους ανεμιστήρες να δουλεύουν στο φουλ, την αδρεναλίνη στο κόκκινο από την αυξανόμενη ισχύ, κατάλαβα ότι κάτι δεν πήγαινε καλά δευτερόλεπτα προτού μυρίσω τον μαγικό καπνό. Κατέβασα διακόπτες αμέσως και αφού κρυώσαμε όλοι μαζί, άρχισα να ψάχνω την βλάβη. Αυτό που βλέπετε στην φωτογραφία δεν το περίμενα. Όπως δεν περίμενα ότι η αντίσταση με την τιμή των 20 Ωμ είναι κατά παραγγελία του εργοστασίου! Τεσπά το πρόβλημα αυτό λύθηκε με την παραλληλία δύο αντιστάσεων με τιμές 22 Ωμ και 220 Ωμ. Νέα τιμή 20 Ωμ ακριβώς! Αυτό που μένει είναι να αντικαταστήσω και τις τέσσερις φυσικά . Δεν το έκανα όσο είμαστε κάτω στο /A, γιατί μετά είχαμε άλλα.
Τα γεννητούρια της Ουρανίτσας! (αλλά αυτό είναι μιά άλλη ιστορία!)

Friday, 3 April 2015

Καλή Ανάσταση!


Θα πάω στο χωριό, για να ταΐσω τα γατιά!
(και να δοκιμάσω τον Collins 30L-1!)


Καλές γιορτές και Καλή Ανάσταση σε όλους και όλες!

Happy Orthodox Easter everybody!

Saturday, 31 January 2015

Ode to Joy or otherwise upgrading my Collins 30L-1



In view of the forthcoming permanent move to Kalamata, I have begun to restore or improve the radios that will be used in the shack. After the TS-830s next in line was the JEWEL of my collection. 
The Collins 30L-1 amplifier!
So far I have changed the boards of rectification and filtering circuits of high voltage with a K6HM HV diode filter board

I purchased it before many years to install it sometime. Well, this "sometime" came now! Using the electronics lab of my business partner (I stress, business!) Tolis SV1EDY, I've started doing it. A few nights ago, I installed the high voltage Board, since, as you can see in the pictures the old had visible problems. The stand-off pillars are hollow and the bolts are passing all the way to the underchassis. Notice the star washer at the lower right one!
I lit it, saw voltages and shine off. 

HV no load = 1920 VDC
HV load = 1830 VDC
Bias voltage no load = -170 VDC
Bias voltage load = -120 VDC
No bang! 
Last night I changed the pull-down resistance of the antenna relay and did some voltage measurements. Full report of the proceedings will be given at the end of the project. Until then I invite you to rejoice with me!

Εν όψη της επικείμενης μόνιμης μετακόμισής μου στην Καλαμάτα, έχω αρχίσει να αποκαθιστώ ή και να βελτιώνω τα μηχανήματα τα οποία θα χρησιμοποιηθούν στο shack. Μετά το TS-830s σειρά έχει το ΚΟΣΜΗΜΑ της συλλογής μου. 

Ο ενισχυτής Collins 30L-1!
Μέχρι στιγμής του έχω αλλάξει τις πλακέτες των κυκλωμάτων ανόρθωσης και φιλτραρίσματος της υψηλής τάσης με μία πλακέτα κατασκευής του K6HM. Την αγόρασα πρίν πολλά χρόνια για να την εγκαθιστούσα κάποια στιγμή. Ε, αυτή η "κάποια στιγμή" ήρθε τώρα. Χρησιμοποιώντας το εργαστήριο του εμπορικού συνεργάτη μου(το τονίζω, εμπορικού!) Τόλη SV1EDY,έχω ξεκινήσει.



Μερικές νύχτες πριν, εγκατέστησα την πλακέτα Υψηλής Τάσης δεδομένου ότι, όπως μπορείτε να δείτε στις φωτογραφίες, η παλιά, είχε εμφανή προβλήματα.

 Τον άναψα, μέτρησα τις τάσεις και τον έκλεισα. 

HV no load = 1920 VDC
HV load = 1830 VDC
Bias voltage no load = -170 VDC
Bias voltage load = -120 VDC
Κανένα ΜΠΑΜ!
Χτες βράδυ άλλαξα την pull-down αντίσταση του ρελέ της κεραίας κι έκανα μερικές μετρήσεις. Πλήρης αναφορά των πεπραγμένων θα δοθεί στο τέλος του όλου εγχειρήματος. Μέχρι τότε σας καλώ να χαρείτε μαζί μου!